The S401 flow meter is designed to measure compressed air in a user-friendly and affordable way. The S401 is a thermal mass flow meter, so it is not necessary to set the compressed air pressure and temperature separately to measure the flow. The S401 flow meter is also very suitable for measuring other gases, e.g. nitrogen and other technical gases. The S401 sensor technology guarantees a very fast and accurate measurement. The flowmeter can store two calibration curves, allowing the sensor to be used in two different gases without loss of accuracy. The optional color display shows all measured values, such as flow and total consumption. The display can also be used to manage sensor settings such as pipe diameter, gas type or output settings. The S401 flowmeter offers several signal output options, such as analog and pulse. Alternatively, a MODBUS RTU interface can be used to access all measured values ​​via the digital interface. The S401 flowmeter can be easily installed, without having to depressurize your compressed air system. Also disassembling the flowmeter for calibration, for example, is no problem at all. Various settings such as gas type, flow unit, reference standards can be set at the factory as required. If it is necessary to change the settings on site, the free S4C-FS software for Android phones can be used to wirelessly access the flowmeter settings. Special wishes regarding the measurement of compressed air and/or gas flows, please feel free to contact us. CHARACTERISTICS - Thermal mass flow, independent of pressure and temperature changes - Measure standard flow, mass flow and consumption - Installation under pressure by 1/2” ball valve - Two calibration curves can be stored in the internal memory of the sensors The two calibration curves allow the sensor to operate in two different gases with the highest precision are used - Speed, flow rate, consumption and temperature are displayed - Choice of gas type (some gases require real gas calibration!) - The integrated display allows users to see the actual flow rate and total consumption - IP65 housing provides rugged protection in harsh industrial environments - Isolated mA and pulse output signals or Modbus / RTU interface - Very fast response time, high accuracy and large measuring range - Pipe diameters from DN25 to DN500A
More Information
Material Metalen delen 1.4404, Behuizing PC + ABS
Classification IP65 / CE RoHS, FCC
Power 15…30VDC / 200 mA
Working pressure 0… 5,0 Mpa (>1,6 Mpa veiligheidsframe nodig)
Display Colour LED optioneel
Anologue output 4…20mA, geisoleerd
Pulse output Signaa: Geïsoleerd, normaal open, max 30 VDC, 20 mA. Schaal: 1 puls/meeteenheid
Modbus output Geïsoleerd RS485 met Modbus/RTU
Pipe diameter DN25 … DN300
Accuracy 1,5% van meetwaarde + 0,3% van full scale. Optioneel 1% van gemeten waarde.
Response time > 10 metingen/sec.
Working temperature Sonde -30...140ºC
Behuizing -30...70ºC
Behuizing inl. display -10...50ºC